Saudi Journal of Gastroenterology
Home About us Instructions Submission Subscribe Advertise Contact Login    Print this page  Email this page Small font sizeDefault font sizeIncrease font size 
Users Online: 814 
REVIEW ARTICLE
Year : 2019  |  Volume : 25  |  Issue : 6  |  Page : 335-340

Lumen-apposing metal stents in management of pancreatic fluid collections: The nobody's land of removal timing


1 Department of Medical Sciences, Gastroenterology Unit, City of Health and Science, Turin, Italy
2 Department of Medical Sciences, Gastroenterology Unit, University of Turin, City of Health and Science, Turin, Italy

Correspondence Address:
Dr. Ludovica Venezia
Gastroenterology Unit, AOU Cittá della Salute e della Scienza, Corso Bramante 89, 10100 Turin
Italy
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sjg.SJG_166_19

Rights and Permissions

Pancreatic fluid collections (PFCs) develop as a result of damage to the major or peripheral pancreatic ducts, complication due to acute or chronic pancreatitis, trauma or iatrogenic causes. PFCs include pancreatic pseudocysts (PPs) and walled-off necrosis (WON). PFCs usually resolve spontaneously and are asymptomatic, but if they persist, increase in dimension or became symptomatics, therapeutic intervention is required. Available therapeutic interventions include surgical, percutaneous, and endoscopic drainage. The endoscopic approach is nowadays considered the first line-treatment of PFCs due to various advantages when compared with surgical or percutaneous drainage: decreased morbidity, length of hospital stay, and reduced costs. In the last few years, the endoscopic ultrasound (EUS)-guided transmural drainage, initially with plastic stents, gained popularity. More recently, fully covered self-expanding lumen-apposing metal stents (LAMS) have been demonstrated to be both, safe and effective with high clinical and technical success, reducing the risk of perforation, peritoneal leakage, migration and facilitating the drainage of necrotic contents. In the last few years, several studies evaluating the safety and efficacy of LAMS and their differences with plastic stents have been performed, but literature on the removal timing of this device and associated complications is still limited. The aim of this review is to analyze studies reporting information about the retrieval timing of LAMS and the related adverse events.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1453    
    Printed53    
    Emailed0    
    PDF Downloaded113    
    Comments [Add]    

Recommend this journal